HV48300 Max SE
The ultimate commercial solution engineered with larger 314Ah automotive-grade cells—fewer connections, maximum density, maximum performance. IP55 outdoor-rated with multi-layer active fire suppressio
-
SafeTier-1 Automotive-grade LFP 314Ah Cells
Multi-level BMS Monitoring and Active Fire Suppression
NFPA 68/69, UL 9540, UL 9540A, UL1973 Compliant
-
All-WeatherAir-cooling System
Built-in Module-level Fans
IP55 Rated Water & Dust Proof Cabinet
-
ScalableModular by Design, Scalable on Demand:
Scale Seamlessly to MWh-level Capacity -
FlexibleWide Voltage Operation Range
Universal Mounting Structure
Support Various Inverter Models
-
SmartRemote Monitoring and Upgrading with Pytes Battery Cloud
-
Local Delivery & ServicesLocal Stock for Faster Delivery
Local Team Provides Comprehensive Services
| Battery Module | |
|---|---|
| Battery Chemistry | Lithium Iron Phosphate (LFP) |
| Battery Module Nominal Voltage | 51.2V |
| Battery Module Nominal Capacity | 44.8~57.6V |
| Battery Module Nominal Capacity | 314 Ah |
| Battery Module Energy | 16.076kWh |
| Weight |
262 ± 11 lb / 119 ± 5 kg |
| System | ||
|---|---|---|
| Max. Battery Pack Internal Configuration 1 | 7S2P | 15S1P |
| Rated Energy | 200.70kWh | 215.04kWh |
| Rated Power | 100.35kW | 107.52kW |
| Operating Voltage | 313.6 ~ 4032 V | 672~ 864V |
| Rated Charge/Discharge Current | 140 A*2 | 140A |
| Peak Charge/Discharge Current | 170 A*2 (@60 s) | 170 A (@60s) |
| General | ||
|---|---|---|
| Dimensions(WxDxH) | 47 x 43 x 89 in (1200 x 1100 x 2250 mm) | |
| Weight (lb / kg) | 5310.94 / 2409 | 5511.56 / 2500 |
| Ingress Protection Rating | IP 55 | |
| Cycle Life 2 | 6000cycles | |
| Warranty 3 |
Battery system: 3 Years 4 Battery module: 10 Years |
|
| Environmental | |
|---|---|
| Operating Temperature |
Charging: 32°F ~ 131°F (O°C~SS°C) Discharging: -13°F ~ 131°F (-25°C~55°C) |
| Operating Altitude | ≤6561.68 ft(2000m) |
| Relative Humidity | 5%-95 %, non-condensing |
| Fire Suppression System | |
|---|---|
| Level 1: Detection & Ventilation | Hazardous gas detection activates ventilation system |
| Level 2: Aerosol Suppression | Heat and smoke detection activates aerosol fire suppression system |
| Level 3: Pressure Relief | The explosion relief valve opens automatically if internal pressure exceeds safe limits |
| Level 4: Fire Hose Connection Port | Equipped with a fire hose connection port for firefighter hose attachment |
| HVAC | |
|---|---|
| Max. Cooling Capacity | 5000 W (L35) |
| Max. Heating Capacity | 2500 W |
| Ingress Protection Rating | IP55 |
| Compliance | |
|---|---|
| Certifications | UL 9540 Ed.3 (2023), UL 9540A, UL 1973, UN 38.3 |
1. Flexible Configuration:
1P (1*BCU): Number of connectable BMUs ranges from 1 to 15. Voltage Range: 44.8V x (1 ~ 15) ~ 57.6V x (1 ~ 15).
2P (2*BCU in paralle): Number of connectable BMUs ranges from 1 to 7 for each BCU. Voltage Range: 44.8V x (1 ~ 7) ~ 57.6V x (1 ~ 7).
2. Operating conditions: 77°F (25°C), 0.5C @ 90% DOD, ret @70% (EOL).
3. Warranty: 3 years for the whole battery system, 10 years or 6000 cycles for the battery (whichever comes first).
4. Optional 2 year warranty extension available for purchase.