DS-RF Selective Formaldehyde module HCHO Module
DS-RF selective formaldehyde module can detect HCHO, VOC, TVOC, t & RH at the same time.
Brief Introduction
DS-RF selective formaldehyde module can detect HCHO, VOC, TVOC, t & RH at the same time. The module combines selective HCHO sensor with advanced electronic control technology, converting HCHO concentration into PPM directly. The module realizes the detection of VOC and TVOC based on fuel cell technology. DS-RF selective HCHO module is free from the influence of the interference gases, such as C2H5OH, C6H6, NH3, CO, etc. DS-RF selective HCHO module is pre-calibrated in the factory and can be integrated into your system directly.
Typical Applications
Smart home
Air purifier
Air conditioners
Portable devices
Wearable devices
HCHO detector
Key Features
Selective detection of HCHO
Detection of HCHO, VOC, TVOC, t, RH together
VOC & TVOC detection based on fuel cell tech.
High precision
Fast response
Long service life
High stability
Diagram
note:1 All dimension is in mm
2 The tolerance is ±0.15mm
Definition of Pins
PIN |
DEFINITION |
Pin1 |
Vin(5V) |
Pin2 |
GND |
Pin3 |
RXD (0~3.3V data input) |
Pin4 |
TXD( 0~3.3V data output) |
Technical Specification
MODEL |
DS-RF |
||
Detection Principle |
Micro fuel cell |
||
Detectable Gas |
HCHO |
VOC |
TVOC |
Detection Range |
0-1ppm |
0-10ppm |
0-10ppm |
Overload |
5ppm |
100ppm |
100ppm |
Resolution |
0.001ppm |
0.001ppm |
0.001ppm |
Accuracy |
±30ppb or ±10%(25±3℃ &50±5%RH) whichever is greater |
/ |
/ |
Input Voltage |
4.5~7VDC |
||
Response Time (T90) |
<120S |
||
Operating temperature range |
-40℃~60℃ |
||
Operating Humidity Range |
10%-90%RH(non-condense) |
||
Lifetime |
6years in air |
||
Warranty Period |
12 months |
||
Weight |
10g |
Cross Sensitivity of HCHO
Interference Gas |
Concentration of Interference Gas(ppm) |
Concentration of HCHO(ppm) |
C2H5OH |
10 |
<0.1 |
C6H6 |
10 |
0 |
CH3COOH |
10 |
0 |
NH3 |
10 |
0 |
CO |
1000 |
6 |
H2 |
1000 |
6 |
Communication Protocol
Ø General Settings
Module makes use of serial communication.
Communication configuration parameters are:
Baud rate |
9600 |
Data bits |
8 bits |
Stop bit |
1 bit |
Parity bit |
None |
Ø Communication Command
There are two communication types: active upload type and Q&A type. The default type is active upload and it sends gas concentration once every second. Commands are as follow:
0 |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
start |
reserved |
C-high |
C-low |
C-high |
C-low |
C-high |
C-low |
± |
t-high |
t-low |
RH-high |
RH-low |
Checksum |
0XFF |
0X05 |
HCHO ppb |
HCHO ppb |
VOC ppb |
VOC ppb |
TVOC ppb |
TVOC ppb |
t +:0/-:1 |
t ℃ |
t ℃ |
RH % |
RH % |
XX |
Gas concentration = C-high*256 + C-low 1ppm = 1000ppb
temperature = t-high + (t-low / 100 )
humidity = RH-high + (RH-low/ 100)
Switch to Q&A mode:
0 |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
Start |
Reserved |
Switch command |
Q&A |
Reserved |
Reserved |
Reserved |
Reserved |
Checksum |
0XFF |
0X01 |
0X78 |
0X41 |
0X00 |
0X00 |
0X00 |
0X00 |
0X46 |
Switch to active upload mode:
0 |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
Start |
Reserved |
Switch command |
Active upload |
Reserved |
Reserved |
Reserved |
Reserved |
Checksum |
0XFF |
0X01 |
0X78 |
0X40 |
0X00 |
0X00 |
0X00 |
0X00 |
0X47 |
To read temperature and humidity:
0 |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
Start |
Reserved |
Command |
Reserved |
Reserved |
Reserved |
Reserved |
Reserved |
Checksum |
0XFF |
0X01 |
0X3F |
0X00 |
0X00 |
0X00 |
0X00 |
0X00 |
0XC0 |
To return:
0 |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
Start |
Command |
± |
t-high |
t-low |
RH-high |
RH-low |
Reserved |
Checksum |
0XFF |
0X3F |
+:0/-:1 |
t ℃ |
t ℃ |
RH % |
RH % |
0x00 |
XX |
temperature = t-high + (t-low / 100 )
humidity = RH-high + (RH-low/ 100)
To read gas concentration:
0 |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
Start |
Reserved |
Command |
Reserved |
Reserved |
Reserved |
Reserved |
Reserved |
Checksum |
0XFF |
0X11 |
0X43 |
0X00 |
0X00 |
0X00 |
0X00 |
0X00 |
0XAC |
To return:
0 |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
Start |
Command |
C-high |
C-low |
C-high |
C-low |
Reserved |
Reserved |
Checksum |
0XFF |
0X43 |
HCHO ppb |
HCHO ppb |
VOC ppb |
VOC ppb |
0x00 |
0x00 |
XX |
Gas concentration = C-high*256 + C-low
Reviews